Lock Type: | Single | |
Extra Facilities: | Non-Return Value at Inlet | |
Internal Components | Gas Specific | |
Loading: | Float | |
Surface Mounting: | Possible | |
Concealed: | Possible | |
Panel Mounting: | Possible | |
On Line Servicing: | Not Possible |
. . . a trust for better life care | Log on to: www.anaesthesiaequipment.in , www.lifecareproduct.com
Thursday, October 28, 2010
LCP Medical Gas Outlet
Friday, October 15, 2010
Thursday, September 30, 2010
LCP CONTROL PANNEL
Fully automatic in operation and requiring no action LCP Control Panel is pneumatically operated by the service gas on pressure differential basis and needs no electrical supply to operate. It will continue to function therefore, should there be failure in electrical supply.
It is equipped with a shuttle valve and takes on automatically from empty cylinder bank to full cylinder bank.
The panel is enclosed in a metal cabinet with a hinged front cover. The cover is fitted with a lock to prevent unauthorized access, and can be swung open for maintenance.
A visual indication of the manifolds is provided by the three gauges within the control panel, clearly visible to through the transferred cover, these gauges indicates the pressure of right and left hand cylinder banks and the supply pressure from the control panel to the distribution system
The panel is supplied with sensing facilities to provide visual signals and other ancillary services.
The panel is supplied with sensing facilities to provide visual signals and other ancillary services.
In addition the panel is fitted with audio alarm indication for change over from empty cylinder bank to filled cylinder bank.
Mox regulator
We offer compressed medical gas regulator that comes in both single stage and double stage versions. These compressed medical gas regulator are directly mounted on the cylinder valve outlet, or on oxygen therapy and anesthetic apparatus to minimize high cylinder pressure and to maintain consistency.
Features:
- It has an integrated high quality color coded pressure gauge for both cylinder and outlet pressure of (0-250) and (0-16) kg/cm2.
- The regulator also consists of high tensile brass forged main body, bonnet and components of extruded brass rod.
- A qualitative rubber diaphragm and pin valve seat ensures efficient regulator performance.
- An inbuilt safety valve prevents chances of a high pressure build up in the regulator.
REGULATOR SPECEFICATIONS
MODEL NAME ( LCP -MOX Regulator) | GAS SERVICE | GAUGE Pressure | MAX OUTLET PRESSURE |
SINGLE STAGE SINGLE GAUGE | OXY/N20/CO2 | 0-250 KG/CM2 | 4 KG/CM2 |
SINGLE STAGE DOUBLE GAUGE(In the upper pic) | OXY/N20/CO2 | 0-250 KG/CM2 | 4 KG/CM2 |
DOUBLE STAGE DOUBLE GAUGE | OXY/N20/CO2 | 0-250 KG/CM2 | 4 KG/CM2 |
Tuesday, September 28, 2010
LCP SYSTEMA
Special Features:
•3 Tube Hypoxia guard Rota meter-pneumatic device ensures no nitrous oxide flow, if oxygen flow is lower than 0.5ltr/min. approx. Minimum 25 %( ±5%) Oxygen (1:3 mixed ratio between O2 & N2O) in Surgery gas mixture.
•Oxygen locked N2O supply Oxygen failure warning device.
•Higher efficiency forged regulators & yokes with S.S fittings.
•Panel mounted high & low pressure display gauges and audio visual Oxygen
•Failure Warning Device (AUDIO & VISUAL).
•High precision pressure relief cum non return valve.
•Halothane Change over mechanism with oxygen flush (open & close circuit)
•Oxygen & Nitrous oxide gas inlet point each 3 nos. & 1 no. Airgas Point at the back.
•Standard Magill’s circuit, All rubber antistatic tested.
•Trolley made of power coated Stainless steel table-top tray, Modified monitoring accessories.
•Drawer top stainless steel tray 5”dia antistatic breaking castor wheel.
•Oxygen outlet for driving ventilator (Double)
•Large diameter (63mm) O2 & N2O gauge each two for high visibility & clarity O2 & N2O operating pressure (4.22kgf/cm2) display gauge each one.
•Central pipe line connection & 10 liters W/C cylinder carrier facility.
Structure: MS structure.
Provision for: Tec vaporizer, Circle absorber (Optional at extra cost).
SIZE: 1690mm x 800mm x 640mm (H x W x D) [can be changed according to customers need]
Warranty: 12 Months from the date or Purchasing.
Circle Absorber - LCP
Circle Absorber: (LCP-CA)
Specification:
Transparent Light weight canister.
Double Chamber Adult size.
Soda lime Capacity 1800 gms.
Completely leak proof.
Easy cleaning - fully autoclavable.
Reversible Soda lime canister fitted to control head by means of a central tube which is screwed into the head with a large plastic hand wheel.
Transparent Light weight canister.
Double Chamber Adult size.
Soda lime Capacity 1800 gms.
Completely leak proof.
Easy cleaning - fully autoclavable.
Reversible Soda lime canister fitted to control head by means of a central tube which is screwed into the head with a large plastic hand wheel.
Circle Absorber Duo
LCP CA DUO |
Circle Absorber Duo: (LCP-CAD)
FEATURES:
International standard circle absorber.
Easy to refill.
Transparent light weight canister.
Single chamber (provision for more than one chamber at an extra cost).
Soda Lime capacity 0.8kg/chamber.
Completely leak proof.
Easy cleaning-fully autoclave able.
Pop-off valve provided for gas scavenging.
International standard circle absorber.
Easy to refill.
Transparent light weight canister.
Single chamber (provision for more than one chamber at an extra cost).
Soda Lime capacity 0.8kg/chamber.
Completely leak proof.
Easy cleaning-fully autoclave able.
Pop-off valve provided for gas scavenging.
SPECIFICATION:
Circle body with 22 mm (F) ISO connector.
All joints are made leak-proof by taper & 'O' Ring.
All body made of Brass Chromium plated.
All gaskets are made of neoprene rubber.
Plastic corrugated tube.
Poly carbonate canister.
Circle body with 22 mm (F) ISO connector.
All joints are made leak-proof by taper & 'O' Ring.
All body made of Brass Chromium plated.
All gaskets are made of neoprene rubber.
Plastic corrugated tube.
Poly carbonate canister.
Mark-IV anaesthesia Machine
FEATURES of LCP MARK-IV
A.THE APARATUS :
Tubular Rigid Steel section duly powder coated with rear system wheel. Sufficient space provided at the top level of Lower Drawer along with Guarded Table Top Steel Tray. Top Tray provided at eye level for keeping Monitoring Equipments. Four antistatic Castor wheels with brake have been fitted for easy mobility.
B. ATTACHMENT :
-i) Rotameters: 230 mm long accurately Calibrated Rotating Bobbing Flowmeters.
Oxygen : 100 ml / min to 8 LPM & Nitrous Oxide : 200ml / min to 12 LPM
-ii) Ether: Eather vaporizer with Bottle (50 cc to 300 cc) supplied as standard accessories. Goldman vaporizer may be provided as per customer’s choice.
-iii) Non-Return-cum-Pressure Relief valve: Blow off excess pressure in the circuit. Release pressure 100 CM H2O+10% , H2O-10%.
-iv) Change over Unit: Emergency oxygen Flush Button is provided at table Top Level on the front . flow range 35 LPM calibrated to 60 PSI (+5,-5)
-v) Regulator: 2 No's Nitrous Oxide Regulator (cut off facility) & 2 No's Oxygen Preset Regulator, been provided with 2 No's Nitrous Oxide & 2 No's Oxygen pressure gauge(2.5” ф) fixed on bend gauge post.
-iv) Alarm: Oxy failure alarm, if flow of oxygen (02) goes flow below 2.5 LPM
C. PATIENT CIRCUIT : 1.Bag mount, 2.Rebreathing Bag (2 ltrs), 3.Corrugated Tube (Anti static), 4.Expiratory Valve, 5.Angle Mount, 6.Catheter Mount, 7.Face Mask (Adult & child) with tube, 8.Adopted Plug In Hose.
D. OPTIONAL : Circle absorber System : Twin Canister Circle Absorber System is provided with Swiveling facility. Canisters & inspiratory valve have quick - fit Tapper fitting with Rubber ‘O’ Ring for leak proof seal & easy maneuver ability. Bag Mount & APL valve Assembly have swivel arms for easy accessibility.
E. WARNINGS : Hypoxic mixture may be deliver from the system when gasses other than oxygen, nitrous oxide are used .
Call us at: (+)91-33-24532467
LCP MARK-IV |
LCP Economy Model
LCP-ECON
AN EXCLUSIVE NITRO LOCKING SYSTEM AT ROTAMETER LEVEL
INTRODUCTION:-
LCP’s Anaesthesia Machine with exclusive Nitrous Oxide locking system has been developed in consultation with number of Anesthetic & emphasis has been given on the highest level of “PATIENT SAFETY”. Keeping in view the objectives of successfully fulfilling the day to day essential Anaesthesia needs & requirements of the actual user.
INTEGRATED SAFETY FEATURES :-
Unlike the limitations of other Nitrous Oxide Lock Systems where presence of supply pressure of oxygen at cylinder level is sufficient to allow flow of Nitrous oxide through its Rotameters.LCP’s ‘ISF’ works as a true Fail-Safe System as it allows flow of Nitrous Oxide only in presence of oxygen at Rota meter level ,locks the flow of Nitrous Oxide in the absence of flow of oxygen through its Rota meters.
THE APPARATUS :-
Construction: Tubular Rigid Steel Section, Powder Coated.
Self for Ventilator: Sufficient space provided at the top level of lower drawer to place ventilator.
Table Top: Guarded Table Top Provided with a stainless Tray.
Instrument Tray: Top Tray Provided at eye level for keeping Monitoring Equipments.
ATTACHMENT:-
ROTAMETERS: 230 mm long accurately calibrated rotating bobbin flow meters.
Oxygen: 100 ml/min to 8 LPM
Nitrous Oxide: 200 ml/min to 12 LPM
EATHER VAPORIZER: The Vaporizer of Eather or Halothane is supplied as standard accessories.
EMERGENCY UNIT: Emergency oxygen flush button is provided at the back bar & guarded to avoid accidental passing. FLOW RANGE: 35LPM calibrated at 60 PSI (+5%,-5%)
PATIENT CIRCUIT:- Standard Magill’s Circuit consisting of Bag Mount – 01 No corrugated Hose -01 No.Angle Mount -01 No., Catheter Mount -01 No., Face Mask -01 No.,Rebreathing Bag -01 No.,Key Spanner -02 No.
OPTIONAL:-
Circle Absorber System: Twin Canister Circle Absorber System is provided with Swiveling facility. Canisters & inspiratory valve have quick – fit Tapper fitting with Rubber ‘O’ ring for leak proof seal & easy maneuver ability. Bag Mount & APL valve Assembly have swivel arms for easy accessibility.
Call us at 033-24532467